nVent ERIFLEX FleXbus Splicing Blocks
 Passe o cursor para ampliar a imagem ou clique para aumentar
        
        Passe o cursor para ampliar a imagem ou clique para aumentar
       
        nVent ERIFLEX FleXbus Splicing Blocks
The nVent ERIFLEX Splicing Blocks are designed for extending FleXbus conductors with a strong, compact design that ensures high short-circuit resistance and easy installation in various positions. They support extensions above 25 meters for 220-960mm² conductors and above 15 meters for 1280-1810mm² conductors. The blocks feature a powder-painted aluminum connector to prevent galvanic corrosion and nonmagnetic stainless steel screws.
The flexible insulated cover provides Class II insulation, resists high temperatures up to 115°C, has an IP55 rating for water and dust protection, and is treated to resist rodent and termite attacks. The blocks comply with IEC 61 439-1 and IEC 60 364 standards and carry CE and UKCA certifications.
                                      Detalhes
          
          
        
        
                        
              
        
  
  
      
  
        
                  
   
  
      
    
              
              
        
      
    
              
            
                    
            
          
          
  
  
        
  
    
            
        
        
      
    
    
      
      
    
    
  
  
      
      
    
              
  
        
                                            Imagens da aplicação
          
          
        
        
                                            Recursos
          
          
        
        
                        
            
        
  
    
               
  
    
                    
  
  
      
      
  
    
      
    
    
      
  
      
  
              
  
  
      
      
  
    
      
    
    
      
  
      
  
              
  
  
      
      
  
    
      
    
    
      
  
      
  
              
  
  
      
      
  
    
      
    
    
      
  
      
  
                
      
 
          
  
      
    
  
        
                                            CAD
          
          
        
        
                        
            
          
  
      
    
  
        
                                            Vídeo
          
          
        
        
                        
            
        
  
  
                                                
            
       
  
          
                                      
            
       
  
          
                    
      
    
  
        
                                                                                                      
Caracteristicas
- Strong and compact design for high short-circuit resistance
- High-temperature resistant cover treated against rodent and termite attacks
- Compliance with IEC standards and CE/UKCA certifications
- Multiple connection options: vertical, horizontal, flat position, or on edge
- Durable and reliable performance in various applications
- IP55 water and dust resistance
- UV-resistant material
- Flame-retardant, Low smoke, Halogen-free
Especificações
| Espessura do isolamento | 0.12" | 
| Espessura do isolamento | 3 mm | 
| Min Installation Temperature | 5°C | 
| Rigidez dielétrica | 20kV/mm | 
| Min Installation Temperature | 41°F | 
| Em conformidade com | IEC® 60695-2-11 (Glow Wire Test 960 °C);IEC® 61439.1;IEC® 61439.1 Class II;IEC® 60364 | 
| Halogen Free Rating | UL® 2885;IEC® 60754-1;IEC® 62821-2 | 
| Low Smoke Rating | UL® 2885;IEC® 61034-2;ISO 5659-2 | 
| IP Rating | IP55 | 
| Rodent & Termite Proof | Tested as per GB/T 34016-2017 & DIN EN 117 | 
| UV Resistance Rating | UL® 2556;UL® 854 | 
| Flammability Rating | UL® 94V-0 | 
| Temperatura de trabalho | -50 to 115 °C | 
| Temperatura de trabalho | -58 to 239 °F | 
| Insulation Elongation | 500 % Max | 
Brochura
Manual de instalação/folha de instruções
Certifications
        CE, ERIFLEX FleXbus Splicing Block 
      
      
              
          English
        
      
          
      EN IEC 60364, EN IEC 61439
    
      
        IEC 61439-1 Splicing Block
      
      
              
          English,French
        
      
          
      IEC 61439-1
    
      
        IEC 61439-1 Class II Splicing Block
      
      
              
          English,French
        
      
          
      IEC 61439-1 Class II
    
      
        UKCA, ERIFLEX FleXbus 
      
      
              
          English
        
      
          
      EN IEC 61439-1; EN IEC 60364; EN IEC 61914
    
      

- Aviso
- Os produtos nVent devem ser instalados e utilizados apenas conforme indicado nas fichas de instrução do produto e materiais de treinamento da nVent. As fichas de instrução estão disponíveis em www.nVent.com e com nossos representantes de atendimento ao cliente nVent. A instalação inadequada, uso incorreto, aplicação incorreta ou outra falha qualquer em seguir completamente as instruções e avisos da nVent podem levar ao mau funcionamento do produto, danos à propriedade, lesões corporais graves e morte, e/ou anular sua garantia.
 
                 
                 
             
             
             
             
             
             
             
             
             
             
             
             
             
            